Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage 


Vol. 33,  No. 1, pp. 62-65, Feb.  2018
10.14346/JKOSOS.2018.33.1.62


PDF
  Abstract

The rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the “Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems“ cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than 300㎡, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.

  Statistics
Cumulative Counts from November, 2022
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.


  Cite this article

[IEEE Style]

백창선 and 박인선, "Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage," Journal of the Korean Society of Safety, vol. 33, no. 1, pp. 62-65, 2018. DOI: 10.14346/JKOSOS.2018.33.1.62.

[ACM Style]

백창선 and 박인선. 2018. Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage. Journal of the Korean Society of Safety, 33, 1, (2018), 62-65. DOI: 10.14346/JKOSOS.2018.33.1.62.