Experimental Study on the Determination of Optimum Thickness of RC Deck Slabs by 100, 120 MPa High-Strength Concrete 


Vol. 33,  No. 4, pp. 38-45, Aug.  2018
10.14346/JKOSOS.2018.33.4.38


PDF
  Abstract

Bridges are structures where safety must be ensured. Generally, the destruction mechanism of bridge deck shows punching shear. Lately, the high-strength concrete is often used to increase the lifespan of bridges. The benefits of using the high-strength concrete are that it increases the durability and strength. On the contrary, it reduces the cross-section of the bridges. This study suggested the optimal thickness of bridge deck with application of high-strength concrete and the study evaluated its structural performance experimentally. The evaluation result shows that 180 mm and 190 mm of thickness are optimal for 100MPa and 120MPa high-strength concrete bridge deck respectively.

  Statistics
Cumulative Counts from November, 2022
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.


  Cite this article

[IEEE Style]

배재현, 황훈희, 박성용, "Experimental Study on the Determination of Optimum Thickness of RC Deck Slabs by 100, 120 MPa High-Strength Concrete," Journal of the Korean Society of Safety, vol. 33, no. 4, pp. 38-45, 2018. DOI: 10.14346/JKOSOS.2018.33.4.38.

[ACM Style]

배재현, 황훈희, and 박성용. 2018. Experimental Study on the Determination of Optimum Thickness of RC Deck Slabs by 100, 120 MPa High-Strength Concrete. Journal of the Korean Society of Safety, 33, 4, (2018), 38-45. DOI: 10.14346/JKOSOS.2018.33.4.38.