An Experimental Study on Smoke Generation of Rubber Floor for Railway Vehicle 


Vol. 33,  No. 4, pp. 15-20, Aug.  2018
10.14346/JKOSOS.2018.33.4.15


PDF
  Abstract

In this study, we have performed the Cone Calorimeter test and Smoke density test in accordance with ISO 5660-1 and ASTM E662 respectively to check the smoke production characteristics of rubber flooring materials for railway vehicle. Early in the ASTM E662 test, more smoke was produced in the flame mode test than non-flame mode test, but later more smoke was produced in non-flame mode test. The correlation(R2) between TSR(Total Smoke Release) by ISO 5660-1 and Ds(Specific Optical Density) by ASTM E662 Flame mode was 0.782. The R2 between TSR by ISO 5660-1 and Ds by ASTM E662 Non-flame was 0.930.

  Statistics
Cumulative Counts from November, 2022
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.


  Cite this article

[IEEE Style]

박영주, "An Experimental Study on Smoke Generation of Rubber Floor for Railway Vehicle," Journal of the Korean Society of Safety, vol. 33, no. 4, pp. 15-20, 2018. DOI: 10.14346/JKOSOS.2018.33.4.15.