A experimental Study on Insulation Breaking Fire Case of Starter Motor B Terminal 


Vol. 34,  No. 5, pp. 55-62, Oct.  2019
10.14346/JKOSOS.2019.34.5.55


PDF
  Abstract

In this paper, we introduce a case of a fire accident during parking of a large truck that is repeatedly occurring. The shape and location of the combustion and electrical singularity commonly found in other vehicle fire accidents could limit the starter motor as the ignition section. In addition, it was possible to confirm the electrical melting singularity that could act as a cause of ignition between the start motor B terminal and the start motor enclosure. By combining the above investigations and investigations, it was possible to estimate the electric fire expressed from insulation breaking of the starter motor B terminal, and by using the renewable starter motor comparison product mounted on the fire vehicle, an experiment was performed to reproduce the ignition process from the starter motor under specific conditions. So. It is hoped that this will raise awareness about vehicle fires, which can lead to large fires or casualties, share the risks of using starter motors for regeneration, and help in the rapid and accurate investigation of similar vehicle fires in the future.

  Statistics
Cumulative Counts from November, 2022
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.


  Cite this article

[IEEE Style]

우승우, 박정만, 현병수, 남정우, 박우식, 김진표, 조영진, 고재모, 박남규, "A experimental Study on Insulation Breaking Fire Case of Starter Motor B Terminal," Journal of the Korean Society of Safety, vol. 34, no. 5, pp. 55-62, 2019. DOI: 10.14346/JKOSOS.2019.34.5.55.

[ACM Style]

우승우, 박정만, 현병수, 남정우, 박우식, 김진표, 조영진, 고재모, and 박남규. 2019. A experimental Study on Insulation Breaking Fire Case of Starter Motor B Terminal. Journal of the Korean Society of Safety, 34, 5, (2019), 55-62. DOI: 10.14346/JKOSOS.2019.34.5.55.